Appliance Repair Morris Connecticut

Advantage Appliance Repair Inc. Rated 5.0 out of 5 stars based on 1 customer reviews

We serviced a
WHIRLPOOL REFRIGERATOR FDB
Model WRF535SWHZ10
Near Morris, CT 06763
Andre
Job Details: 06/04/2025
"Ck unit upon arrival and remove and install right door with closure,name plate and door gasket heat seal gasket for proper suction unit now operating to manufacturers specs"
We serviced a
KITCHENAID RANGE
Model KFDD500ESS10
Near Morris, CT 06763
Andre
Job Details: 04/16/2025
Ck unit upon arrival and remove and install main control board with bake element advance unit into a cycle to 400 degrees and unit got to temp unit now operating to manufacturers specs
We serviced a
KITCHENAID RANGE
Model KFDD500ESS10
Near Morris, CT 06763
Andre
Job Details: 04/09/2025
Ck unit upon arrival and advance unit through cycle check voltage and found voltage at broil element but no voltage at bake element order parts for replacement office will call customer when parts arrive ; ordrng 1 W11598459 (Control)
We serviced a
WHIRLPOOL REFRIGERATOR FDB
Model WRF535SWHZ10
Near Morris, CT 06763
Andre
Job Details: 04/02/2025
Ck unit upon arrival and found door clicking each time door open and close. Remove and found internal portion of door hinge damage on door. Order door with closure and gasket thats rip for replacement customer will contact office once she received door ; ordrng 1 W11435333 (Right door) and 1 Wp12028505ap (Closure) and 1 W11223753 (Name plate) and 1 W10830162 (Gasket right)
We serviced a
MAYTAG DRYER
Model MEDB835DW4
Near Morris, CT 06763
Jimmy R.
Job Details: 02/01/2024
"Tested unit due to dryer would not dry clothes fully this would not happen all the time, checked venting and found vent is short and new checked outside cap and air is blowing strong. Ran unit thew a diagnostics cycle and found 240v to terminal block 120v to each side of heater checked for errors and found F4e3 restricted air flow, f2e1 stuck key checked venting and found lint screen housing blocked with lint causing poor air flow noticed lint seemed to be from slot of moisture collecting in unit, cleaned housing and ran unit thew a sensing cycling vent came back with good flow was coming back with AF AIR flow issue. Let unit run and all operations are now working to specs"
Morris, Connecticut
MAYTAG DRYER
MEDB835DW4
02/13/2024